Siemens Nxairs-12kV Air/gas Insulated Medium Voltage Electrical/power Distribution Panels/switchgear

1. Mode:siemes Nxairs series
2. Voltage: 3.6kv, 7.2kV-12kV
3. Custom switchgears can be provided.

Product Details

SIEMENS NXAirS-12 kV Air Insulation Withdrawable Metal-clad medium-voltage Switchgear

1. Characteristics

· Mechanical dynamic position indicator

·The closing/opening status of disconnecting switch and grounding switch can be indicated respectively on mechanical dynamic position indicator.

·Operating handle socket and control elements are obviously set adjacent to closing/opening indicator of controlled switches.

· All the switch operations can be carried out when high-voltage compartment door closed.

· All the parts and components installation heights meet the requirements of human engineering.

· Options: Capacitive electric indicator can be used to detect feeder or power of busbar.

2. Electric Parameters

- Rated voltage

kV

7.2

12

- Rated frequency

Hz

50

50

-   Rated short-time power frequency withstand voltage (interphase, to-ground)

kV

32

42

- Rated lightning impulse withstand voltage   (interphase, to-ground)

kV

60

75

-   Rated short-circuit breaking current

MAX

kA

40*

40*

- Rated short-time withstand current, 4s

MAX

kA

40*

40*

- Rated short-circuit closing current

MAX

kA

100*

100*

- Rated peak withstand current

MAX

kA

100*

100*

- Rated bus current

MAX

A

4000

4000

- Feeder current1)

A

   

Circuit breaker cabinet

4000

4000

Contactor cabinet

250

160

Disconnecting handcart cabinet

4000

4000

Bus segment cabinet

4000

4000

Bus lifting cabinet

4000

4000

·  *: It is applicable to switchgears outside of contactor cabinet.

3. Overall Dimensions 

Width

mm

Circuit breaker cabinet

 

≤630A

650

1250A~2500A

800

3150A~4000A

1000

Disconnecting handcart cabinet

 

≤2500A

800

3150A~4000A

1000

Transformer used in substation

1000

Bus segment cabinet

 

≤2500A

2×800

3150A

2×1000

Measuring cabinet

800,1000

Lifting cabinet

800,1000

Contactor cabinet

650

Height2)

mm

≤31.5KA

2200

40 kA

2300

Switchgear used in substation

2500

Contactor cabinet

2200

Depth3)

mm

assembled with ordinary circuit breaker

 

≤31.5 kA and bus current≤2500A

1350

≤31.5 kA and bus current≥3150A

1450

40 kA

1450

assembled with solid-closure circuit   breaker

 

≤31.5 kA and bus current≤2500A

1350

≤31.5 kA and bus current≥3150A

1500

40 kA

1500

Contactor cabinet

1350,1500

Weight kg

1250A/31.5 kA standard cabinet

About 850kg

3150A/40 kA standard cabinet

About 1300kg

Note 1) The rated current of switchgear under forced air cooling is up to 4000A;

          2) H1: the height from standard low-voltage compartment top to the ground is 2075mm;

         H2: the height from raising low-voltage compartment top to the ground is 2350mm;

         3) upper outgoing, or bus accessories, bus current ≤ 2500A,cabinet deepens 130mm;

        upper outgoing, or bus accessories, bus current>2500A,cabinet deepens 200mm;

        Backpack plans, rated current ≤2000A, the depth is 460mm;

        Backpack plans rated current >2000A, the depth is 620mm

XD HI-TECH, established in 2007, is one of the excellent manufacturers in China. Come and find siemens nxairs-12kv air/gas insulated medium voltage electrical/power distribution panels/switchgear distributors from our factory. With high precision and good performance, our custom products have a wide application field. Welcome to wholesale our quality products and the PDF display is also offered.