Electrical Cubicle KYN61-40.5 Draw-out HV Metal Enclosed Switchgear

Electrical Cubicle KYN61-40.5 Draw-out HV Metal Enclosed Switchgear is an indoor switchgear, assembly operating under the conditions of three phase 50/60Hz and rated 40.5KV AC voltage.
It complies with GB3906-2006, IEC62271-200 and other relative standards.

Product Details

Electrical Cubicle KYN61-40.5 Draw-out HV Metal Enclosed Switchgear


Introduction:

It is an indoor switchgear, assembly operating under the conditions of three phase 50/60Hz and rated 40.5KV AC voltage.

It complies with GB3906-2006, IEC62271-200 and other relative standards.

 

Features:

●The switchgear and partition boards adopting Al-Zn alloy coated steel plates and frame adopting multiple bending technology make high overall intensity and good earth continuity.

●The switchgear is combined type and the handcart of breaker is floor structure type.

●The new composite insulating vacuum circuit breaker has the characteristics of interchangeability and simple replacement.

●The handcart adopts screw propulsion mechanism, which moves the handcart easily and prevent misoperation to damage the propulsion mechanism.

●All the operations could be done when the cabinet door is closed.

●The interlocking between the main switch, the handcart and the switch cabinet adopts the mandatory mechanism of mechanical locking, meeting the functions of five-preventions.

●The cable room is spacious and can be connected to a number of cables.

●The protection level is IP4X, which effectively prevents the equipment from being invaded by sundries and insect pests.

●The switchgear runs safely and reliably through the harsh condensation, filth and internal arc tolerance test.

 

Service environment:

(1) Normal operating conditions:

- Ambient temperature: -10 ° C ~ 40 ° C

- Daily average RH does not exceed 95%; monthly average RH does not exceed 90%

- The daily average value of steam pressure does not exceed 2.2k Pa and does not exceed 1.8kPa

- the altitude does not exceed 1000 meters;

- the surrounding air is not responsible for any pollution, smoke, password or flammable air, steam or salty fog;

- the external vibration of the switching device and the control device or the terrestrial dither is negligible;

- The secondary electromagnetic interference voltage caused in the system is not more than 1.6kV.

(2) Special operating conditions

- According to IEC60694, GB / T11022, manufacturers and users can agree on special service conditions to deviate from normal service conditions

- In order to prevent condensation, the switchgear needs the heater to be put into use

- When the switch ears are ready and service conditions. The heat problem of the switch ear can be

Solved by ventilation facilities.

 

Applications:

It is mainly used for power transmission & distribution for generators, transformer substations and the industry and mine enterprises. It can also be used to control, protect and monitor electric circuits, and useful to frequent operating conditions.


Technical Parameters:

Items

Units

Parameters

Rated voltage

KV

40.5

Rated frequency

Hz

50

Rated current

A

1250, 1600

Rated closed current (peak)

KA

25, 31.5

4s Thermal stability current

KA

63, 80

Rated dynamic stability current (peak)

KA

25, 31.5

Rated insulation level

1 min power frequency withstand voltage

KV

95

Lighting impulse withstand voltage (peak)

KV

185

Isolation   break 1min power frequency withstand voltage (effective value)

KV

115

Enclosure protection class

KV

215

Protection level


Shell IP4X, IP2X when the isolation room door and circuit   breaker room door opened.

Cabinet body dimension (W×D×H)

mm

1400×2800×2600

1600×2800×2600

Circuit breaker type


HVX-40.5      VD4-40.5  

ZN85-40.5     3AE-40.5