Ggj Type Reactive Power Compensation Device

1. Application fields: substation, factory, mining enterprise, power plants, petroleum& chemical enterprise, steel plants, high-rise building MCC, reactive power compensation places
2. Rated working voltage: 380V
3. Certificates: test report and 3C certificate
4. Custom switchgears are provided.

Product Details
Quality, speed, focus, professionalism and innovation are the service concepts of our company. We have gradually established a good reputation in the field of automatic transfer switch, unitised substation, power distribution box over the years. Enterprise development should be people-oriented, which is to create greater benefits for customers and to meet their needs, as well as to help employees realize their own value. We adhere to the development idea of independent innovation, driven by strategy and culture.

China Qualified GGJ LV Reactive Power Compensation & Power Factor Correction Capacitor Bank Device Supplier

1. Application

The application fields of GGJ LV Reactive Power Compensation & Power Factor Correction Capacitor Bank Device the substation, factory, mining enterprise, power plants, petroleum& chemical enterprise, steel plants, high-rise building MCC, reactive power compensation places.

2. Technical parameters

Items  

parameters

Rated working voltage

AC   380V

Rated insulation voltage

AC   660V

Overvoltage grade

Pollution level

Electric clearance

≥10mm

Creepage distance

≥14mm

Compensation capacity

400kvar-60kvar

Main busbar rated current

516A-87A

Rated short time withstand current

15kA

Rated peak withstand current

30kA

Main circuit breaker current

800A

Main circuit breaker breaking capacity

50kA

Compensation   branch number

12

Output   circuit capacitor capacity

Three-phase

40kvar×7

Three-phase  

30kvar×2

Single-phase

20kvar×3

Output   circuit rated current

44A×7,   57A×2,   94A×3

Compensation   mode

Combination  of three-phase compensation and single phase compensation

Shell protection grade

IP30

Height   (mm)

1800-2200

Width   (mm)

600-1000

Depth   (mm)

300-600

3. Operation conditions

1.  Ambient temperature: the maximum temperature is +40℃ and the lowest temperature is -5℃. The average temperature in 24 hours should be less than +35℃.

2. The relative humidity of ambient air should be less than 50% when the highest temperature is +40℃. The higher relative humidity is allowed at a lower temperature, for example, when the temperature is +20℃, the relative humidity can be 90%. Dewing may happen accidentally due to the change of temperature.

3. Altitude should be less than 2000m.

4. Earthquake magnitude should be less than 8.

5. The place should be free from serious contamination, chemical corrosion, and strong vibration.

6. If the users have special requirements, coordinate with a manufacturer

4. Ordering Instruction

Orderer should offer the following technical document:

1. All types of products include main circuit plan No. and auxiliary circuit plan No.

2. Main circuit system combination sequence drawing

3. Auxiliary circuit electric scheme

4. Cabinet elements list

5. Setting parameters such as voltage, current and time.

6. Other requirements not in accordance with normal use.

We have always believed that professionalism changes the future so that we continue to research and develop every year and committing to upgrading our Ggj Type Reactive Power Compensation Device to a higher level in the world. The company develops together with a diversified business model and a win-win business philosophy with society and partners. We believe that you will be glad with our realistic selling price, high-quality products and solutions and rapid delivery.
Hot Tags: ggj lv reactive power compensation & power factor correction capacitor bank device China, manufacturers, suppliers, factory, wholesale, design, custom, application, PDF, gas insulated switchgear, intelligent switchgear, transfer switch, kiosk substation, medium voltage switchgear, power distribution cabinet