LCD Display Electricity Power Saver Energy Saving Device

1. Application fields: substation, factory, mining enterprise, power plants, petroleum& chemical enterprise, steel plants, high-rise building MCC, reactive power compensation places
2. Rated working voltage: 380V
3. Certificates: test report and 3C certificate
4. Custom switchgears are provided.

Product Details
Our well-equipped facilities and great excellent command throughout all stages of generation enables us to guarantee total customer fulfillment for reactive power compensation device, board panel, Prefabricated substation. We will integrate the details of the service with a professional attitude, spirit and practice to make the performance of the service more humane. At present, the production and operation of products up to thousands of specifications.

China Qualified GGJ LV Reactive Power Compensation & Power Factor Correction Capacitor Bank Device Supplier

1. Application

The application fields of GGJ LV Reactive Power Compensation & Power Factor Correction Capacitor Bank Device the substation, factory, mining enterprise, power plants, petroleum& chemical enterprise, steel plants, high-rise building MCC, reactive power compensation places.

2. Technical parameters

Items  

parameters

Rated working voltage

AC   380V

Rated insulation voltage

AC   660V

Overvoltage grade

Pollution level

Electric clearance

≥10mm

Creepage distance

≥14mm

Compensation capacity

400kvar-60kvar

Main busbar rated current

516A-87A

Rated short time withstand current

15kA

Rated peak withstand current

30kA

Main circuit breaker current

800A

Main circuit breaker breaking capacity

50kA

Compensation   branch number

12

Output   circuit capacitor capacity

Three-phase

40kvar×7

Three-phase  

30kvar×2

Single-phase

20kvar×3

Output   circuit rated current

44A×7,   57A×2,   94A×3

Compensation   mode

Combination  of three-phase compensation and single phase compensation

Shell protection grade

IP30

Height   (mm)

1800-2200

Width   (mm)

600-1000

Depth   (mm)

300-600

3. Operation conditions

1.  Ambient temperature: the maximum temperature is +40℃ and the lowest temperature is -5℃. The average temperature in 24 hours should be less than +35℃.

2. The relative humidity of ambient air should be less than 50% when the highest temperature is +40℃. The higher relative humidity is allowed at a lower temperature, for example, when the temperature is +20℃, the relative humidity can be 90%. Dewing may happen accidentally due to the change of temperature.

3. Altitude should be less than 2000m.

4. Earthquake magnitude should be less than 8.

5. The place should be free from serious contamination, chemical corrosion, and strong vibration.

6. If the users have special requirements, coordinate with a manufacturer

4. Ordering Instruction

Orderer should offer the following technical document:

1. All types of products include main circuit plan No. and auxiliary circuit plan No.

2. Main circuit system combination sequence drawing

3. Auxiliary circuit electric scheme

4. Cabinet elements list

5. Setting parameters such as voltage, current and time.

6. Other requirements not in accordance with normal use.

Our design and production of LCD Display Electricity Power Saver Energy Saving Device have reached the domestic leading level, and we have strong new-product development capabilities. We win many reliable customers by rich experience, advanced equipments, skilled teams, strict quality control and best service. The trust culture formed by our company will be a solid rock to maintain and protect the company's reputation.
Hot Tags: ggj lv reactive power compensation & power factor correction capacitor bank device China, manufacturers, suppliers, factory, wholesale, design, custom, application, PDF, unitised substation, transfer switch, low voltage switchboard, AC switchboard, small torsion spring, LV switch gear
Inquiry