Russian Market Power Factor Correction Equipment for Power Factor Improvement Calculation

1. Application fields: substation, factory, mining enterprise, power plants, petroleum& chemical enterprise, steel plants, high-rise building MCC, reactive power compensation places
2. Rated working voltage: 380V
3. Certificates: test report and 3C certificate
4. Custom switchgears are provided.

Product Details
We'll make every effort and hard work being outstanding and excellent, and speed up our techniques for standing during the rank of global top-grade and high-tech enterprises for auto transfer switch, withdrawable switchgear, tension spring. Sincerely hope we are growing up together with our prospects all over the environment. We focus on research and development of new products, innovative design, precision production, honest sales and professional after-sales.

China Qualified GGJ LV Reactive Power Compensation & Power Factor Correction Capacitor Bank Device Supplier

1. Application

The application fields of GGJ LV Reactive Power Compensation & Power Factor Correction Capacitor Bank Device the substation, factory, mining enterprise, power plants, petroleum& chemical enterprise, steel plants, high-rise building MCC, reactive power compensation places.

2. Technical parameters

Items  

parameters

Rated working voltage

AC   380V

Rated insulation voltage

AC   660V

Overvoltage grade

Pollution level

Electric clearance

≥10mm

Creepage distance

≥14mm

Compensation capacity

400kvar-60kvar

Main busbar rated current

516A-87A

Rated short time withstand current

15kA

Rated peak withstand current

30kA

Main circuit breaker current

800A

Main circuit breaker breaking capacity

50kA

Compensation   branch number

12

Output   circuit capacitor capacity

Three-phase

40kvar×7

Three-phase  

30kvar×2

Single-phase

20kvar×3

Output   circuit rated current

44A×7,   57A×2,   94A×3

Compensation   mode

Combination  of three-phase compensation and single phase compensation

Shell protection grade

IP30

Height   (mm)

1800-2200

Width   (mm)

600-1000

Depth   (mm)

300-600

3. Operation conditions

1.  Ambient temperature: the maximum temperature is +40℃ and the lowest temperature is -5℃. The average temperature in 24 hours should be less than +35℃.

2. The relative humidity of ambient air should be less than 50% when the highest temperature is +40℃. The higher relative humidity is allowed at a lower temperature, for example, when the temperature is +20℃, the relative humidity can be 90%. Dewing may happen accidentally due to the change of temperature.

3. Altitude should be less than 2000m.

4. Earthquake magnitude should be less than 8.

5. The place should be free from serious contamination, chemical corrosion, and strong vibration.

6. If the users have special requirements, coordinate with a manufacturer

4. Ordering Instruction

Orderer should offer the following technical document:

1. All types of products include main circuit plan No. and auxiliary circuit plan No.

2. Main circuit system combination sequence drawing

3. Auxiliary circuit electric scheme

4. Cabinet elements list

5. Setting parameters such as voltage, current and time.

6. Other requirements not in accordance with normal use.

We adhere to market-oriented and technological leadership as the main purpose, and strive to develop new series of Russian Market Power Factor Correction Equipment for Power Factor Improvement Calculation and expand the market. Any requires from you will be paid with our best attention! We strive to improve company performance and corporate reputation.
Hot Tags: ggj lv reactive power compensation & power factor correction capacitor bank device China, manufacturers, suppliers, factory, wholesale, design, custom, application, PDF, Metal Enclosed switchgear, power factor correction equipment, electrical switchgear, electrical switchboard, small torsion spring, intelligent switchgear
Inquiry